AIR-SAVER-LS G1"
Compressed air energy saver
The AIR-SAVER-LS helps end-users to save valuable compressed air from escaping unnecessarily, reducing compressor running hours and thus extending its lifetime, saving energy and operating costs.
The AIR-SAVER-LS G1" (Light Switch) is installed in the compressed air line after the air receiver. The AIR-SAVER-LS G1" is controlled via an internal relay which is connected to an external switch and separate power supply.
A typical installation example is to connect the AIR-SAVER-LS to a light switch. By switching on the lights in the production area, the AIR-SAVER-LS will subsequently open. The saved compressed air flows into the factory compressed air line and the compressor kicks in to produce the air needed to fill the system. At the end of the work-shift you switch off the light(s) and the AIR-SAVER-LS will close accordingly.
The AIR-SAVER is also available as a time controlled option with a week programming feature. This version allows you to set the open and closed position according to customer specific demands. For more information click here
Share
A typical installation of an AIR-SAVER-LS connected to a light switch.
Manual valve opening and closing possible, in case of a power failure.
- At least one air receiver’s worth of compressed air savings per day
- No unnecessary compressor start-up during periods when compressed air is not required
- Compressor, dryer and filter activities are avoided during factory closing hours
- Manual valve opening and closing possible, in case of a power failure
- Very quick and easy to connect to an external (light) switch
- Slow valve opening to avoid “water hammer” in pipe line system
- Brass valve, nickel plated
- Compact design - Easy to install
| 0 - 230 psi |
| 34 - 210 °F |
| 34 - 120 °F |
| 115 VAC or 230 VAC 50/60Hz. |
| Approx. 7W during cycle rotation |
| NEMA13 (IP54) |
| 115 VAC or 230 VAC |
| 1" NPT |
| 30 sec. (90°) |
| Brass valve, nickel plated |
| Yes |
Features
A typical installation of an AIR-SAVER-LS connected to a light switch.
Manual valve opening and closing possible, in case of a power failure.
- At least one air receiver’s worth of compressed air savings per day
- No unnecessary compressor start-up during periods when compressed air is not required
- Compressor, dryer and filter activities are avoided during factory closing hours
- Manual valve opening and closing possible, in case of a power failure
- Very quick and easy to connect to an external (light) switch
- Slow valve opening to avoid “water hammer” in pipe line system
- Brass valve, nickel plated
- Compact design - Easy to install
Specifications
| 0 - 230 psi |
| 34 - 210 °F |
| 34 - 120 °F |
| 115 VAC or 230 VAC 50/60Hz. |
| Approx. 7W during cycle rotation |
| NEMA13 (IP54) |
| 115 VAC or 230 VAC |
| 1" NPT |
| 30 sec. (90°) |
| Brass valve, nickel plated |
| Yes |