| THE JORC-TEC 22 IS DESIGNED TO PROVIDE A SOLUTION FOR THE AUTOMATIC DRAINING OF FILTER, SEPARATORS, RECEIVERS, DRIP LEGS AND OTHER COMPRESSED AIR SYSTEM COMPONENTS WHERE CONDENSATE AND CONTAMINANTS COLLECT. THE DRAINING INTERVAL AND DISCHARGE TIME CAN BE ADJUSTED TO SUIT ALL REQUIREMENTS. |
|
Failure to carry out regular routine draining, either manually or by float draining can have catastrophic results. Compressed air systems can become grossly contaminated and production schedules seriously disrupted - just because a simple duty has been neglected.
The JORC-TEC 22 eliminates the risk of human error and a possible costly aftermath by providing regular controlled system drainage, on time, every time - automatically.
The JORC-TEC 22 unit consists of a solid-state timer coupled to a solenoid valve and only requires a simple installation procedure. The unit is suitable for ALL compressed air system components (aftercoolers, dryers, filters, pressure vessels and piping), regardless of their size or capacity - simply adjust the interval and discharge times to suit the particular compressed air system. |
| | |
|
FEATURES: |
- CE tested
- Fully automatic - no maintenance
- One model for all applications
- Multi voltage 24-240V AC/DC, 50/60Hz
- Simple to install
- IP65 enclosure
- Adjustable interval and discharge times
- Test switch - for routine inspection and depressurisation
- Solid-state timer for long life and reliability
- LED indicating power ON or OFF
- Rugged ABS fire resistant housing
- Small compact design
- Up to 3600 psi and FPM seals
- Large 4.5 mm orifice valve
| |

|
|
Float type drains are notoriously unreliable because they either block up or continuously leak. When float drains block or stick then oil and water enters the air again. As a result, compressed air systems become grossly contaminated and downstream processes seriously spoilt or disrupted.
The JORC-TEC 22 eliminates these risks by providing regular controlled drainage, on time, every time - automatically.
| |
| TIMER: |
SPECIFICATIONS: |
| Interval (OFF) time |
Current consumption |
| Discharge (ON) time |
0.5 or 10 seconds |
| Manual TEST switch |
Yes, micro switch |
| Supply voltage |
24 to 240 VAC/DC 50/60Hz |
| Current consumption |
4 mA maximum |
| Operating temperature |
-40 F to 140 F |
| Environmental protection |
IP65 when installed |
| Housing material |
ABS plastic FR grade |
| Connection |
DIN 43650A |
| Indicator |
LED to indicate power ON or OFF |
| Design standard |
VDE 01 10C |
| VALVE: |
SPECIFICATIONS: |
| Type |
2/2-way direct acting valve |
| In/Out connection size |
1/8" to 1/2" NPT female |
| Maximum working pressure |
230 psi (optional up to 3600 psi) |
| Maximum ambient temperature |
36 F to140 F |
| Maximum media temperature |
194 F |
| Valve body |
Forged Brass, orifice 4.5 mm (23/128") |
| Insulation |
Thermal group H |
| Environmental protection |
IP65 when installed |
| Voltage |
24V to 240V available, see coil for correct voltage |
| Voltage tolerance |
+/- 10% |
| Mounting in any position |
Yes | | |