Condensate Drains, Oil/ Water Separators, Electronic Timers, Solenoid ValvesCondensate Drains, Oil/ Water Separators, Electronic Timers, Solenoid Valves


Flow graph

Poly-element life indicator

A visual check is offered by the indicator in the head of tower 1. The indicator rests on the white element and sinks downwards According to the white element’s remaining adsorption capacity.
 
TEST

The PURO is designed to separate oil from condensate. To check the PURO’s
activated carbon element(s) and the output residue of oil, a TEST valve is located in the front of all units.

Test bottle

All PURO’s come with a test kit reading of 20 ppm. The test bottle has a label
giving an indicative comparison that is mounted on top of tower number two.


Servicing drain valve

Once a year we recommend a thorough cleaning/servicing of the PURO. For health and safety reasons the whole unit can be drained from its water content by opening the servicing drain valve.

Safety kit

For health and safety reasons all PURO units and replacement elements are
supplied complete with a protective clothing kit.
The content of the kit is: face mask, gloves and plastic jacket.

Modular connection GRAND-EXTENDER

Although the overall sizes of the PURO models are compact in design, the larger
models have an additional hook-up feature. The PURO GRAND XTENDER can
be positioned in a 90 degree (corner position) or a 180 degree (flat against the
wall position).

Overflow indicator

It is virtually impossible to overflow the PURO, yet as a precaution the larger
models have an incorporated overflow feature. The overflow indicator also gives a visual indication of the condensate inlet flow rate.

Depressurising feature

The PURO depressurises the condensate immediately at the inlet stage. This feature allows for every type of condensate drain.
(timer controlled, intelligent type or float type).

© 2003 All Rights Reserved, JORC Industrial